Items 141 - 160 of 1486
New surplus
Used
Defective
New
used - cosmetical damage see photos
front plug
supply plug
memory card
as shown on photo
Manual (pdf Download)
Reset all filters
SITAS transformer; Phases: 1; Pn/Pn(S6)(kVA): 0.315 / 1.12; Upri(V): 400 +/- 5%; Usec(V): 230; Isec(A): 1.37; F(Hz): 50...60; Switching size/shielding: II0 / 0; TA/Isokl: 40 / B; IP00; Connection: Screw/flat plug connection; Mounting: Screws; EN 61558-2-1, -2-2, -2-4 >UL/CSA-Recognized Control Transformer Isolation Transformer<
Semiconductor contactor 1-phase 3RF2 AC 15 / 15 A / 40 °C 24-230 V / DC 24 V momentary switching
Siemens Sirius Halbleiterschütz, 3RF1211-0JA16
Circuit breaker size S0 for motor protection, CLASS 10 A-release 7...10 A N-release 130 A screw connection standard switching capacity
Circuit breaker size S0 for motor protection, CLASS 10 A-release 1.4...2 A N-release 26 A screw terminal standard switching capacity
Circuit breaker size S00 for motor protection, CLASS 10 A-release 10...16 A N-release 208 A Screw terminal Standard breaking capacity with transverse auxiliary switch 1NO+1NC
Circuit breaker size S0 for motor protection, CLASS 10 A-release 10...16 A N-release 208 A Screw terminal Standard breaking capacity
Circuit breaker size S00 for motor protection, CLASS 10 A-release 9...12.5 A N-release 163 A Screw connection Standard breaking capacity
Digital monitoring relay for voltage monitoring, 22.5 mm, 0.1-60 V AC/DC over- and under-voltage detection. Supply voltage: AC/DC 24 V DC and AC 50 to 60 Hz, without galvanic isolation from the measuring circuit. Peak delay 0.1 to 20 s. Hysteresis 0.1 to 30 V. 1 changeover contact with or without fault memory. Screw terminals.
Circuit breaker size S0 for motor protection CLASS 10 A release 1.4...2 A N release 26 A screw connection Standard switching capacity!!! Discontinued product!!! The successor is SIRIUS 3RV2. The preferred successor type is >>3RV2011-1BA10<<
CIRCUIT BREAKER. SCREW-TYPE. 75 A
Contact module with 1 contact element, 1 NO, spring-type terminal, for front plate mounting
Circuit breaker size S2 for motor protection, CLASS 10 A-release 42...52 A N-release 741 A Screw terminal Standard breaking capacity
Circuit breaker size S3 for motor protection, CLASS 10 A-release 65...84 A N-release 1170 A Screw terminal Standard breaking capacity
Circuit breaker size S0 for motor protection, CLASS 10 A-release 34...40 A N-release 480 A Screw connection Standard breaking capacity
Circuit breaker size S0 for motor protection, CLASS 10 A-release 18...25 A N-release 325 A screw terminal standard switching capacity
Circuit breaker size S00 for motor protection, CLASS 10 A release 0.22...0.32 A N release 4.2 A Spring-loaded connection Standard switching capacity
Power contactor, AC-3 32 A, 15 kW / 400 V 1 NO + 1 NC, 24 V AC, 50 Hz 3-pole, size S0 Screw terminal
Power contactor, AC-3e/AC-3, 7 A, 3 kW / 400 V, 3-pole, DC 24 V, auxiliary contacts: 2 NO + 2 NC, screw terminals, size: S00, non-releasable auxiliary switch
Power contactor, AC-3 7 A, 3 kW / 400 V 1 NO, 24 V DC 3-pole, Size S00 screw terminal
Items 141 - 160 of 1486