Items 121 - 140 of 964
New sealed
New surplus
New
Refurbished
holding clamps
memory card
as shown on photo
Manual (pdf Download)
Reset all filters
SENTRON, Lasttrennschalter 3LD, Not-Aus-Schalter, 3- polig, Iu: 32 A, Betriebsleistung / bei AC-23 A bei 400V: 11,5 kW, Frontbefestigt, Drehantrieb, rot/gelb, 4-Loch Befestigung der Handhabe
Switch disconnector 3LD3, Iu 40 A main switch 3-pole Rated operating power at AC-23 A at 400V 18.5 kW Front mounting Basic switch with central hole mounting 22.5mm Toggle drive red/yellow 66x66 mm
NH fuse link, NH00, In: 125 A, aM, Un AC: 500 V, front indicator, live grip tabs
Consumer feeder without fuse, direct start AC 400 V, size S00 7.00...10.0 A DC 24 V screw connection for DIN rail mounting, type of coordination 1, Iq = 150 kA 1S (contactor)
Siemens Sirius Halbleiterschütz, 3RF1211-0JA16
Solid-state Contactor, 20A, 48-600V, 3P, 230VAC, ZP, Screw
SS CONT, 30A, 48-600V, 3P, 4-30VDC, ZP, SCREW
SS CONT, 40A, 48-600V, 3P, 230VAC, ZP, SCREW
SIMATIC PXI230 INDUCTIVE SENSOR M18, 2-WIRE, NO 15...34V DC SN=8MM, NOT FLUSH 25MA, IP67 M12 CONNECTOR, TYPE E, F NICKEL-PLATED BRASS
Siemens 3RG7200-3CC00 Neuware (Überschussbestand)
Siemens 3RG7201-3CC00 Neu, unbenutzt
Auxiliary switch block, 40, 4 S DIN EN 50005 screw connection size S00 for auxiliary and motor contactors!!! Discontinued product!!! The successor is SIRIUS 3RH2. The preferred successor type is >>3RH2911-1FA40<<
Front auxiliary switch, 1 NO contact, spring-loaded closure, for 3RT1 contactors
Auxiliary switch block, 13, 1 NO + 3 NC, DIN EN 50012, spring-loaded connection technology, for motor contactors, 4-pole!!! Discontinued product!!! The successor is SIRIUS 3RH2
Auxiliary switch block, 13, 1 NO + 3 NC, DIN EN 50012, spring-loaded connection technology, for motor contactors, 4-pole!!! Discontinued product!!! The successor is SIRIUS 3RH2
Contactor relay, 6 NO + 2 NC, 24 V DC, Size S00, spring-type terminal, Removable auxiliary switch
ET 200pro DSE ST Direktstarter Standard mechanisch schaltend elektronischer Überlastschutz AC-3, 0,9 kW / 400 V 0,15 A...2,00 A ohne Bremskontakt Han Q4/2 - Han Q8/0
ET 200pro RSE ST Reversierstarter Standard mechanisch schaltend elektronischer Überlastschutz AC-3, 0,9 kW / 400 V 0,15 A...2,00 A Bremskontakt AC 400 V Han Q4/2 - Han Q8/0
ET 200pro DSE ST Direktstarter Standard mechanisch schaltend elektronischer Überlastschutz AC-3, 5,5 kW / 400 V 1,50 A...12,00 A ohne Bremskontakt Han Q4/2 - Han Q8/0
Failsafe reversing starter High Feature, Electronic switching, Electronic overload protection up to 0.25 kW / 400 V, Adjustment range 0.3 .. 1 A, PROFIenergy, Option: 3DI/LC module
Items 121 - 140 of 964