Items 161 - 180 of 202
SIRIUS Sanftstarter S0 32 A, 15 kW/400 V, 40 °C AC 200-480 V, AC/DC 110-230 V Schraubklemmen
SIRIUS Sanftstarter 200-480 V 13 A, AC/DC 24 V Federzugklemmen Analogausgang
Power contactor, AC-3 7 A, 3 kW / 400 V 1 NO, 220 V AC, 50 Hz 240 V, 60 Hz, 3-pole, Size S00, Spring-type terminal
Power contactor, AC-3 7 A, 3 kW / 400 V 1 NO, 24 V DC 3-pole, Size S00 Spring-type terminal
Contactor relay, 6 NO + 2 NC, 24 V DC, Size S00, spring-type terminal, Removable auxiliary switch
SCHUETZ BAUGROESSE 0 3POLIG AC-3, 4 KW, 400 V / 380 V HILFSSCHALTER 11 (1NO+1NC) WECHSELSTROMBETAETIGUNG AC 230/220V 50HZ, 276/264V 60HZ
SENTRON, measuring device, 7KM PAC4200, LCD, L-L: 690 V, L-N: 400 V, 5 A, 3-phase, Modbus TCP, optional Modbus RTU / PROFINET / PROFIBUS / DI/DO, apparent/active/reactive energy / cos phi, harmonics: 2.-64., THD, class 0.2 acc. to IEC61557-12 or cl. 0.2S acc. to IEC62053-22, wide-range pwr sup. unit AC/DC, screw terminals
Siemens SENTRON 3LD2003-0TK53, Switch disconnector 3LD, emergency switching-off switch, 3- pole, 16A
SENTRON, Switch disconnector 3LD, emergency switching-off switch, 3- pole, Iu: 16 A, operating power / at AC-23 A 400 V: 7.5 kW, front-mounted, rotary operating mechanism, Red / yellow, 4-hole mounting of the handle
SIRIUS safety relay Output expansion 4RO with relay enabling circuits 4 NO contacts plus Relay signaling circuit 1 NC contact Us = 24 V DC screw terminal
Hilfsschütz, 2 S + 2 Ö AC 110 V 50 / 60 Hz Schraubanschluss Baugröße S00
Auxiliary switch block, 80 E, 4 NO EN 50011 Screw terminal for contactor relays, 4-pole
Leistungsschütz, AC-3e/AC-3, 9 A, 4 kW / 400 V, 3-polig, DC 24 V, Hilfskontakte: 1 Ö, Schraubanschluss
Power contactor, AC-3 32 A, 15 kW / 400 V 1 NO + 1 NC, 24 V AC, 50 Hz 3-pole, size S0 Screw terminal
Circuit breaker size S00 for motor protection, CLASS 10 A-release 0.22...0.32 A N-release 4.2 A screw terminal Standard switching capacity
Circuit breaker size S00 for motor protection, CLASS 10 A-release 0.45...0.63 A N-release 8.2 A screw terminal Standard switching capacity
Circuit breaker size S00 for motor protection, CLASS 10 A-release 0.55...0.8 A N-release 10 A screw terminal Standard switching capacity
Leistungsschalter Baugröße S00 für den Motorschutz, CLASS 10 A-Auslöser 2,2...3,2 A N-Auslöser 42 A Schraubanschluss Standardschaltvermögen
Circuit breaker size S00 for motor protection, CLASS 10 A-release 5.5...8 A N-release 104 A screw terminal Standard switching capacity
Circuit breaker size S00 for motor protection, CLASS 10 A-release 10...16 A N-release 208 A Spring-type terminal Standard switching capacity
Circuit breaker size S0 for motor protection, CLASS 10 A-release 18...25 A N-release 325 A Screw terminal Standard switching capacity
Items 161 - 180 of 202