Items 41 - 60 of 183
PROFIBUS bus onnector with axial cable outlet for Industry PC, SIMATIC OP, OLM; Transmission rate 12 Mbit/s; terminating resistor with isolating function, Metal enclosure
PROFIBUS FC RS 485 Plug 180, PROFIBUS connector with FastConnect connection plug and axial cable outlet for Industry PC, SIMATIC OP, OLM, Transfer rate: 12 Mbit/s, terminating resistor with isolating function, Plastic enclosure
SIMATIC RF, MV Steckleitung, konfektioniert, zwischen ASM 456, RF160C, RF170C, RF18XC und Reader oder Verlängerungskabel für ASM 456, RF160C, RF170C, RF18XC mit RF, MV, MOBY PUR, Trailing, Länge 2m.
MICROMASTER 420 WITH BUILT IN CLASS A FILTER 3AC 380-480V +10/-10% 47-63HZ CONSTANT TORQUE POWER 4 KW OVERLOAD 150% FOR 60S VARIABLE TORQUE POWER 4 KW 202 X 149 X 172 (H X W X D) PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C W/O AOP/BOP
SINAMICS G120C RATED POWER 0,55KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFINET-PN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSAA 173X73X178(HXWXD) EXTERNAL 24V
ET 200pro RSE ST Reversierstarter Standard mechanisch schaltend elektronischer Überlastschutz AC-3, 0,9 kW / 400 V 0,15 A...2,00 A Bremskontakt AC 400 V Han Q4/2 - Han Q8/0
Failsafe reversing starter High Feature, Electronic switching, Electronic overload protection up to 0.25 kW / 400 V, Adjustment range 0.3 .. 1 A, PROFIenergy, Option: 3DI/LC module
Solid-state contactor 3-phase 3RF2 AC 51 / 30 A / 40 °C 48-600 V / 4-30 V DC 3-phase controlled screw terminal Blocking voltage 1200 V
Circuit breaker size S0 for motor protection, CLASS 10 A-release 1.1...1.6 A N-release 21 A screw terminal Standard switching capacity
Circuit breaker size S0 for motor protection, CLASS 10 A-release 2.8...4 A N release 52 A screw terminal Standard switching capacity
Circuit breaker size S0 for motor protection, CLASS 10 A-release 10...16 A N-release 208 A screw terminal Standard switching capacity
SINAMICS Netzfilter für 5kW Smart Line Module Eingang: 3AC 380-480V, 50/60Hz
MICROMASTER 420 built-in class A filter 200-240 V 1 AC+10/-10% 47-63 Hz constant torque 0.37 kW overload 150% for 60 s square-law torque 0.37 kW 173x 73x 149 (HxWxD) degree of protection IP20 ambient temperature -10+50 °C without AOP/BOP
MICROMASTER 420 built-in class A filter 200-240 V 1 AC+10/-10% 47-63 Hz constant torque 0.55 kW overload 150% for 60 s square-law torque 0.55 kW 173x 73x 149 (HxWxD) degree of protection IP20 ambient temperature -10+50 °C without AOP/BOP
MICROMASTER 420 built-in class A filter 380-480 V 3 AC +10/-10% 47-63 Hz constant torque 5.5 kW overload 150% for 60 s square-law torque 5.5 kW 245x 185x 195 (HxWxD) degree of protection IP20 ambient temperature -10+50 °C without AOP/BOP
MICROMASTER 4 PROFIBUS module For mechanical reasons, for MM4 FX/GX the connector 6GK1500-0EA02 must be used
AS-Interface Montageplatte K60 für Kompaktmodule K60 für Wandmontage für 2 Flachkabel AS-i Leitung (gelb) und AS-i Leitung 24 V (schwarz)
Motoranschlussleitung JZ-HF 5 m, 6x1,5 mm2, Stecker 9-polig Spezial-PVC-Schlauchleitung hochflexibel, selbstverlöschend und flammwidrig
CIRCUIT BREAKER FOR MOTOR PROTECTION UP TO 25A WITH AUXILIARY CONTACTS 2NO WITH SCREW TERMINALS A-RELEASE 2.4 TO 4A N-RELEASE 48A
SIMATIC S7-1200, Digitalausgabe SM 1222, 8 DO, Relais 2A
Items 41 - 60 of 183